Description:
|
rptrInfoResetEvent NOTIFICATION-TYPE
OBJECTS { rptrInfoOperStatus }
STATUS current
DESCRIPTION
"In a system containing multiple managed
repeaters, the rptrInfoResetEvent notification
conveys information related to the operational
status of a repeater. This notification is sent
on completion of a repeater reset action. A
repeater reset action is defined as a transition
to the START state of Fig 9-2 in section 9 of
[IEEE 802.3 Std], when triggered by a management
command (e.g., an SNMP Set on the rptrInfoReset
object).
The agent must throttle the generation of
consecutive rptrInfoResetEvent notifications for
a single repeater so that there is at least
a five-second gap between notifications of
this type. When notifications are throttled,
they are dropped, not queued for sending at
a future time. (Note that 'generating' a
notification means sending to all configured
recipients.)
The rptrInfoResetEvent is not sent when the
agent restarts and sends an SNMP coldStart or
warmStart trap. However, it is recommended that
a repeater agent send the rptrInfoOperStatus
object as an optional object with its coldStart
and warmStart trap PDUs."
REFERENCE
"[IEEE 802.3 Mgt], 30.4.1.3.2, nRepeaterReset
notification."
|
|
Information:
|
Automatically extracted from IETF RFC 2108.
|
|
Disclaimer: The owner of this site does not warrant or assume any liability or responsibility for the accuracy, completeness, or usefulness of any information available on this page (for more information, please read the complete disclaimer).