Description:
|
dot1dTpAgingTime OBJECT-TYPE
SYNTAX Integer32 (10..1000000)
UNITS "seconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The timeout period in seconds for aging out
dynamically-learned forwarding information.
802.1D-1998 recommends a default of 300 seconds."
REFERENCE
"IEEE 802.1D-1998: clause 14.7.1.1.3"
|
|